NEWS
News Center
您现在所在的位置:首页 > News Center
SIMATIC WinCC V13 Released for Delivery
发布时间:2016-07-20

Functionality

Engineering system

Highlights

  • Support of the expanded portfolios of SIMATIC S7-1500 and S7-1200 controllers
  • Support of the 2nd generation Basic Panels
  • Cooperation of WinCC with STEP 7 across projects
  • Intuitive User Interface with maximum ease of use
  • Universal library concept
  • Simple processing of projects with different engineering versions
  • Investment protection due to migration
  • Automatic search for software updates

Support of the expanded portfolios of SIMATIC S7-1500 and S7-1200 controllers
WinCC V13 supports the communication between different HMI devices and the new SIMATIC S7-1500 and S7-1200 controllers of the SIMATIC S7 controller family. Both portfolios have been expanded by additional controllers. Due to the integration of STEP 7 and WinCC into the TIA Portal the symbolic addressing of data can easily be used in the HMI. WinCC V13 also supports the new alarm and diagnostic concept of the S7-1500 controllers for HMI devices.

Support of the 2nd generation Basic Panels
The completely innovated 2nd generation SIMATIC HMI Basic Panels will be released for delivery in Q1/ 2014 (80906101). The units with their high-resolution widescreen displays and additional function keys can be configured with WinCC V13. The intuitive device change with integral size adaptation enables users to easily switch to the new devices.

Cooperation of WinCC with STEP 7 across projects
Especially during the engineering phase of automation tasks several persons may have to work simultaneously on one project. With the TIA Portal V13 and the PLC-Proxy function, control and visualization tasks can be developed in parallel. Using a PLC Proxy, the data to be visualized can be taken over from a STEP 7 or STEP 7 V5.4 Update 3 project into the visualization project, in order to configure the panel in parallel.

Intuitives User Interface with maximum ease of use
Editors that are matched to the configuration task and process, plus latest Windows technologies, form the basis for the intuitive HMI concept of WinCC V13. The integration of different editors into a uniform working environment ensures that all the latest data are available to the user, ensuring a complete overview of the project data at any time.

Universal library concept
A universal library concept is available for re-using often required program sections and for easy standardization of certain programs. Elements such as blocks, tags, alarms, HMI images, image s, single modules or complete stations can be stored with their parameters in local or global libraries. They are then available for further programming jobs or configurations.

Simple processing of projects with different engineering versions
WinCC V13 supports the processing of projects from WinCC V12 in the compatibility mode. After processing in V13 such projects can be used again in a V12 engineering environment. It is thus not necessary to upgrade projects when changing the engineering version, which simplifies the handling of different projects.

Investment protection due to migration
WinCC V13 offers a migration of WinCC flexible 2008 SP2 or SP3 projects and also of WinCC V7.2 projects, thus protecting one-time investments.

Automatic search for software updates
The TIA-Portal V13 enables users to check whether new updates or support packages are available for the installed software. They can then be downloaded and installed, if required.

WinCC Runtime Software

WinCC Runtime Advanced

SIMATIC WinCC Runtime Advanced is the high-performance visualization software for simple, machine-related visualization tasks. It can be used as single-user solution for all automation applications in manufacturing and process industries and in building automation.

Highlights

  • New innovative designs and styles
  • Innovated controls and s
  • Multitouch & gestures

New innovative designs and styles
A special editor enables the creation of central innovative designs and styles for HMI devices. These can also be stored and versioned as s in libraries. By assigning styles to a device, a single step in the engineering can immediately change the appearance of all visualization s. This functionality is available in Runtime Advanced for Comfort Panels and 2nd generation Basic Panels.

Innovated controls and s
The design of the basic s, elements and controls has been innovated. The visualization can thus be created with a modern appearance.

Multitouch & gestures
WinCC Runtime Advaned offers the possibility to implement two-hand operation for multitouch without elaborate engineering. Standard animations support the user with the application of his function and in this way ensure safe operation of critical steps in the production plant. Easy navigation and zoom in lists, tables and documents is now possible via gestures.

WinCC Runtime Professional

SIMATIC WinCC Runtime Professional is a PC-d operator input and control system for the visualization and control of processes, production sequences, machines and plants, in all industries - for simple single-user systems up to distributed multi-user systems and solutions with web-clients across sites.
SIMATIC WinCC Runtime Professional is d on a further development of WinCC Runtime V7.0 SP3 and includes access to WinCC archives via OPC HDA, OPC A&E / OPC- servers and WinCC OLE-DB/OLE-DB. The basic package also includes API for runtime for the use of disclosed programming interfaces.

Highlights

  • Redundancy as option
  • Enhanced diagnostics with the PLC Code Viewer
  • Unicode

Redundancy as option
The use of WinCC server pairs increases the system availability.
If one of the two server computers fails the second computer will take over the control of the system. When the failed server returns to service the contents of all message and process value archives will be copied to the returned partner.

Enhanced diagnostics with the PLC Code Viewer
The PLC Code Viewer enables the status of function blocks to be represented and its malfunction to be traced on a PLC (S7-1200 and S7-1500).
The status of a S7Graph function block (e.g. step name, step number, error status) can be indicated via a control element. An extended control can be started out of this element to indicate the PLC Code concerned and the PLC Network.
No installation of STEP 7 is required on the runtime to display the PLC Code.

Unicode
The support of Unicode (UTF-16) enables different languages (e.g. Western Europe and Asia) to be used in one WinCC Project and simultaneously transferred from the engineering system to runtime.
An name in Unicode data format can be used for each runtime (e.g. tag name).

Runtime options for WinCC

Options for scalable plant configurations

  • WinCC Server for WinCC Runtime Professional:
    for building a powerful client /server system
  • WinCC Redundancy for Runtime Professional
    for building a powerful redundant client /server system
  • WinCC Client for WinCC Runtime Professional:
    for building a powerful client /server system
  • WinCC WebNavigator for WinCC Runtime Professional:
    for operator input an control of plants via the Internet, company Intranet, or LAN
  • WinCC Sm@rtServer for SIMATIC Panels and WinCC Runtime Advanced:
    for the remote access to panels / single-user station options for runtime extensions
  • WinCC Recipes for WinCC Runtime Advanced / WinCC Runtime Professional:
    for managing data records
  • WinCC Logging for WinCC Runtime Advanced / WinCC Runtime Professional:
    for managing data records
  • WinCC Audit for WinCC Runtime Advanced and SIMATIC Panels:
    for recording operator actions in an audit trail and electronic signature
  • SIMATIC Logon:
    central administration of WinCC users troughout the plant; options for IT and business integration; plant intelligence
  • WinCC DataMonitor for WinCC Runtime Professional:
    for indication and evaluation of current process conditions and historical data on office PCs with standard tools; options for individual system expansions
  • WinCC ControlDevelopment:
    for the creation of customer-specific WinCC .net s in a VB/C# develpment environment for PC-d systems

System Requirements

All editions of WinCC V13 have been released for use under the following operating systems:

32-Bit Operating systems

  • Windows 7 Home Premium SP1 (only WinCC Basic)
  • Windows 7 Professional SP1
  • Windows 7 Enterprise SP1
  • Windows 7 Ultimate SP1
  • Windows XP won't be supported

64-Bit Operating systems

  • Windows 7 Home Premium SP1 (only WinCC Basic)
  • Windows 7 Professional SP1
  • Windows 7 Enterprise SP1
  • Windows 7 Ultimate SP1
  • Windows 8.1 (only WinCC Basic)
  • Windows 8.1 Professional
  • Windows 8.1 Enterprise
  • Windows Server 2008 R2 StdE SP1 (not WinCC Basic)
  • Windows Server 2012 R2 StdE


Processor

RAM

Graphics

Operating System

Recommended PC/PG hardware

Intel® Core™ i5-3320M 3.3 GHz
or better

8 GB

1920x1080

64-bit

Compatibility with other SIMATIC products

Side-by-side installation with all other SIMATIC products

  • WinCC Basic/Comfort/Advanced V13 can be installed on one omputer in parallel with STEP 7 V5.4 or V5.5, STEP 7 Micro/WIN, STEP 7 V10.5/V11/V12, WinCC V11/V12, WinCC flexible (2008 and higher) and WinCC (V7.0 SP3 and higher)..
  • WinCC Professional V13 can be installed on one omputer in parallel with STEP 7 V5.4 or V5.5, STEP 7 V10.5/V11/V12, WinCC V11/V12 (except WinCC Professional), WinCC flexible (2008 and higher). The parallel installation with WinCC V6/V7 is not permitted.


  • The following virus scanners have been tested with WinCC V13:
    - Symantec Endpoint Protection 12.1
    - Trend Micro Office Scan Corporate Edition 10.6
    - McAfee VirusScan Enterprise 8.8
    - Kaspersky Anti-Virus 2014
    - Windows Defender (Windows 8.1 and higher)